An Automatic Circuit Recloser (ACR) is a smart protective device that interrupts fault currents, aiming to enhance the reliability of distribution systems. Its key function is to automatically isolate a feeder section in case of a fault, such as a short circuit.
The Outdoor Recloser Switch is a three-phase indoor power distribution device available in voltages ranging from 11kv, 24kv, to 33kv. The standard 24kv vacuum circuit breaker is suitable for protecting and controlling electrical equipment in industrial, mining, power plant, and substation environments. This switch is particularly suited for applications requiring oil-free operation, low maintenance, and frequent switching. It can be configured as pole top switches within central cabinets, double-layer cabinets, or fixed cabinets, providing control and protection for high-voltage electrical equipment.
We offer a range of VCB (vacuum circuit breaker) auto recloser circuit breakers, including 11kv and 33kv auto reclosers, along with other electrical power equipment to meet your needs.
1. Ambient air temperature must range from -5°C to +40°C, and the average temperature within 24 hours should not exceed +35°C.
2. This equipment is intended for indoor installation and operation. The altitude of the operation site should not exceed 2,000 meters above sea level.
3. At the maximum temperature of +40°C, the relative humidity should not exceed 50%. However, higher humidity is permissible at lower temperatures, such as 90% at +20°C. However, considering temperature fluctuations, occasional moderate dew formation is possible.
4. The installation gradient should not exceed 5 degrees.
5. Install the equipment in locations free from severe vibrations, shocks, and areas that may erode electrical components.
6. If you have any specific requirements or questions, please consult the manufacturer for further guidance.
The Outdoor Recloser Switch, often called a recloser pole, is a high-voltage switchgear that incorporates its own control and protection mechanisms. This device is capable of automatically monitoring the current flowing through the main circuit. In the event of a fault, it can promptly disconnect the fault current based on inverse time-limit protection principles. Moreover, it is designed to perform multiple reclosing operations, following a predefined delay and sequence, to ensure system stability and reliability.
1.Q: Are you a manufacturer or trader?
A:We are all, Main business of the company low-voltage switchgear, power distribution cabinet, explosion-proof cabinet design, production and system programming.
2.Q: Whether to support OEM/ODM?Can you design the equipment according to our size?
A: Of course, we can customize any product according to customer requirements, and we can provide design solutions and solutions.
3.Q: Why should I buy from you instead of someone else?
A: First of all, we can provide all customers with very professional support consisting of IT consultants and service teams.Secondly, our main engineers have more than 20 years of experience in power distribution equipment development.
4.Q:What about the delivery time?
A:Generally, our delivery time is around 7-15 days about. While, it depends on the requirement of customers and the
quantity of products.
5.Q:What about the shipment?
A:We can arrange shipment by DHL, FedEx, UPS,etc.of course, customers can also use their own freight forwarders.
6.Q:How about the terms of payment?
A:Supported T/T、Paypal、Apple Pay、Google Pay、Western Union,etc. Of course we can discuss on this.
7.Q:Difference Between Auto Recloser Circuit Breaker and Circuit Breaker
A:Recloser vs circuit breaker are as follows: the pole mounted auto recloser is a kind of high-voltage switchgear with its own control and protection functions; it can automatically detect the current through the main loop of the recloser, protect the fault current automatically according to the reverse time limit in the event of failure, and coincide multiple times according to the predetermined delay and sequence. A automatic recloser circuit breaker is a switching device that can close, carry and open current under normal loop conditions and can close, carry and open current under abnormal loop conditions within a specified period of time.
8.Q:Vacuum Circuit Recloser Construction And Automatic Circuit Recloser Operation
A:The arc extinguishing principle of the auto recloser circuit breaker is: like any kind of high-voltage switch, extinguishing the arc depends on the interrupter chamber. The interrupter is the heart of a high-voltage switch. When the movable and static contacts of the switch are separated, under the action of high electric field, the media particles around the contacts become ionized, thermally free and collisionally free, thus producing an electric arc.
As one of auto recloser manufacturer, we manufacture VCB recloser circuit breaker according to its working principle of vcb. If the moving and static contacts are in an absolute vacuum, when the contacts are opened and closed, no arc is generated because there is no material present, and the circuit is easily broken. If you want to know more details about VCB breaker working principle, please contact us.